Fit only explicitly failed, rebound raw source contours into a new patch.
Original coefficient artifacts are opaque external references. The caller
verifies their bytes and actual tolerance/corner/orientation policy before
supplying identities. All saved populations and target eligibility are
checked before any fit. Raw ordinals never become patch coefficient indices.
A contour with E observed edges needs at most E adaptive spans: every split
partitions a positive integer edge range. Each exact source triangle emits
at most three cut edges, giving a conservative preplan bound 3F. The new
budget is actual E, without forcing one span per edge; this prevents budget
exhaustion but cannot guarantee finite conditioning or tolerance success.
Original policy and measured E/F/bounds survive every requested outcome.
Only newly fitted cubics pass through the official selected-basis converter.
Inputs stay unchanged during the synchronous call. Progress callbacks run
before/after raw planes and target fits; throwing fails without a value and
abort stops later work. A synchronous numeric fit cannot be interrupted from
inside its solve. No timer, host, source normal or original coefficient is
read. Complete qualifies requested patch tolerance only, not original curves,
surface error, continuation, phase correspondence or transverse jets.
Fit only explicitly failed, rebound raw source contours into a new patch. Original coefficient artifacts are opaque external references. The caller verifies their bytes and actual tolerance/corner/orientation policy before supplying identities. All saved populations and target eligibility are checked before any fit. Raw ordinals never become patch coefficient indices.
A contour with E observed edges needs at most E adaptive spans: every split partitions a positive integer edge range. Each exact source triangle emits at most three cut edges, giving a conservative preplan bound 3F. The new budget is actual E, without forcing one span per edge; this prevents budget exhaustion but cannot guarantee finite conditioning or tolerance success. Original policy and measured E/F/bounds survive every requested outcome. Only newly fitted cubics pass through the official selected-basis converter.
Inputs stay unchanged during the synchronous call. Progress callbacks run before/after raw planes and target fits; throwing fails without a value and abort stops later work. A synchronous numeric fit cannot be interrupted from inside its solve. No timer, host, source normal or original coefficient is read. Complete qualifies requested patch tolerance only, not original curves, surface error, continuation, phase correspondence or transverse jets.