One partition sound passes through on its way out of the room.
Contributes area * 10^(-transmissionLoss / 10) to the area-weighted
composite transmittance in analyzeAutoMovieAcoustics. A negative loss is
refused, because a partition cannot transmit more energy than reaches it, and
a loss high enough to underflow every partition's transmittance to zero turns
the composite loss into a gap.
One partition sound passes through on its way out of the room.
Contributes
area * 10^(-transmissionLoss / 10)to the area-weighted composite transmittance inanalyzeAutoMovieAcoustics. A negative loss is refused, because a partition cannot transmit more energy than reaches it, and a loss high enough to underflow every partition's transmittance to zero turns the composite loss into a gap.