Transition start, metres of jointed course arclength from its first centre; finite.
Transition end in the same units; finite, strictly greater than from with finite separation.
Signed target for chart +u at to, in the construction's frame; direction only, unscaled.
One C2 material rotation over a jointed axis, preserving its centreline and section planes.
The base transported frame is unchanged through
from. Atto, remove the targetupdirection's component along the actual tangent and measure its signed angle from the base chart axisutowardsv. Use the shortest angle in (-pi, pi], choosing positive pi for an antipodal target. Connect zero to that angle with the zero-first/second-derivative quintic Hermite, then carry the same constant rotation relative to the base frame beyondto. This is not repeated projection of a fixed world direction along the remaining course.Engine admission requires finite increasing stations with representable positive separation and a finite nonzero target whose projected length exceeds 1e-9 of its full length, the existing jointed-up conditioning policy. It rejects some finite nonparallel directions: limiting the projection condition number below 1e9 limits amplification of input/frame/dot-product error, without guaranteeing one absolute angle error. It is not an anatomical tolerance or an exact-parallel predicate. Stations use the jointed course's physical arclength; they are not an outline's normalized pole parameter. The caller owns the signed anatomical target.