The part's frame along its stations: the section plane at each station.
The front view's two edges: the section's extremes along +u and -u.
What owns the quarters' fullness at each station.
The part's name: unique in its tree, it names the lofted chain and the face a seed or a trim refers to.
Control points of every section's periodic cubic B-spline, a positive multiple of 4 of at least 8, so each touch is a knot.
Which ends close in a point, each a smooth dome.
Uniform phases of the tessellated rings of the part, a positive integer.
The side view's two edges: the section's extremes along +v and -v.
Stations of principal output sections, metres, strictly increasing. Continuous direct shoulder/top sources remain authoritative between them. Generic girth requires every retained contour/fullness knot here, regardless of diagnostic label. Outside source controls retain their original functions; internal interpolation and axis knots require no extra layers.
Discriminator.
A part drawn from its own orthographic views in its own frame: the leaf of a construction tree, lofted by the engine into one section chain.
At every station along the part's axis the four outlines give a box about the axis. The front view sees the part along the section plane's
vaxis, so its two edges are the section's extremes alongu; the side view sees it alongu, so its two edges are the extremes alongv. The section touches each side of the box once, at the polar angles 0,pi / 2,piand3 pi / 2of the plane's chart (the+u,+v,-uand-vdirections), with zero angular slope there, and the fullness owner sets how full each quarter between those touches is. The outlines own the extremes, the fullness owns the quarters, and the diagonals are never an owner.Engine admission:
stationsstrictly increasing; every outline at least two knots by strictly increasing station; each box holding its axis strictly inside it, or that station is left out with a diagnostic;ordera positive multiple of 4 of at least 8;samplesa positive integer. Direct shoulder/top sources retain their original continuous functions at every site without requiring a layer there. Generic girth's coefficient representation requires every in-domain contour/fullness knot as a declared station. Outside controls may retain an original scalar parameter without emitting layers. Each actual pole must remain the same zero-valued singular endpoint of that parameter, with the same inward side. A parameter endpoint alone declares no cap; preserving an old native field requires the removed cap's actual effects to vanish on the kept interval.