    The orthonormal page basis a view resolved to.

    The published basis locates page coordinates in world space on the projection plane. Orthographic projection discards source depth, so page coordinates alone cannot recover the original 3D point; the rounded published axes also need not invert the unrounded derivation exactly.

    normal is the reversed view direction, right is up hint × normal, and up is normal × right. For a reflected ceiling plan right is negated, so that basis is left-handed (right × up = -normal). A derived drawing rounds every component to six decimals, so unit length holds only to that precision.

    interface IAutoMovieDrawingFrame {
        normal: IAutoMovieVector3;
        origin: IAutoMovieVector3;
        right: IAutoMovieVector3;
        up: IAutoMovieVector3;
    }
    Index

    Unit world normal of the cut or picture plane, pointing at the viewer.

    World point at page (0, 0), and the point the cut plane passes through.

    Unit world direction of the page +x axis.

    Unit world direction of the page +y axis.