Linear drag in inverse seconds, nonnegative, dividing updated face velocity by 1 + dt * drag. Zero disables this drag term.
Nonnegative depth threshold in metres; a cell is wet only above it. A face beside dry ground remains still unless the wet free surface stands above that ground. Zero still prevents flow from empty cells, while positive thresholds suppress thinner wet films.
Integration step in seconds; strictly positive.
Gravity magnitude in m/s²; strictly positive (standard gravity is 9.80665).
Highest absolute step index, a safe integer within [1, 100000], bounding one replay's iteration count. Seeking beyond it throws.
Strictly positive design depth in metres, used for the Courant comparison and as the upper bound on initial depth. Solved inflow is not capped to it.
Fixed-step integration settings and the budgets validation enforces.
validateFluidDomain checks finite authored scalars and rejects a computed Courant number above one at referenceDepth. Its direct intermediate products can produce NaN for extreme finite inputs, which that comparison does not reject. Initial depths are bounded by referenceDepth, while inflow can raise solved depths beyond it without a new Courant check.