A sampled measurement outside its independently supplied motion acceptance bound.
kind selects actual and limit units: m/s for speed, radians for angle or joint, metres for all other kinds. AutoMovieMotionAudit allocates findings in sample traversal order and labels the responsible segment, joint, constraint or inter-body pair. Every violation is retained; the record contains a measured value and the failed bound rather than a corrected pose or a continuous-time guarantee.
A sampled measurement outside its independently supplied motion acceptance bound.
kind selects actual and limit units: m/s for speed, radians for angle or joint, metres for all other kinds. AutoMovieMotionAudit allocates findings in sample traversal order and labels the responsible segment, joint, constraint or inter-body pair. Every violation is retained; the record contains a measured value and the failed bound rather than a corrected pose or a continuous-time guarantee.