Id of the built element realizing it, or null for a bare junction.
Stable node identity within the network.
Semantic equipment role, checked against the closed vocabulary. Current node/port admission applies the same rules to every role; kind supplies no inferred geometry, load or operating state.
Node-local axis-aligned maintenance volume in metres, such as panel-door swing or filter pull space; null declares no keep-out. Translation by position forms its world box without an equipment-specific rotation or inferred extent.
Typed connection points this node offers; several may belong to the same system.
World position in metres.
Id of the logical space of the served environment the node stands in.
Named operating state of an inline device, or null when the node has no moving part. A valve, a damper and a switch are the same object here.
One fixture, machine, junction, terminal or inline device on the network.
A basin, a sprinkler head, a socket outlet, a diffuser, an air handling unit, a tee in a chase and a shut-off valve are all this record. What separates them is the ports they carry and the volume they need to be serviced in, not a class hierarchy: a media wall that is simultaneously a wall, a powered device and a light source declares the ports for each and stays one node.