Id of the port the medium leaves from; it must be out or bidirectional.
Stable segment identity within the network.
Ids of the penetrations this run passes through, in no particular order.
Outer radius in metres used for clash and clearance; greater than 0.
World centre line in metres with at least two finite points. Its endpoints must lie within 1e-6 metres of their ports; consecutive points must be farther apart than 1e-9 metres. Vertex-based crossing checks do not prove continuous containment along every leg.
Internal cross-section in square metres; greater than 0.
Id of the system this run belongs to.
Id of the port the medium arrives at; it must be in or bidirectional.
One run joining exactly two ports: a pipe, a duct, a conduit, a cable tray.
The centre line is authored in world metres because that is what a clash is measured in, and the radius is what turns that line into the volume the run actually occupies. A run that leaves the space it started in is expected to name the sleeve it went through, which is the only way a wall can be shown to have been drilled on purpose.