The polygon man's bind joints, placed from the person's parameters by
closed-form placement laws alone, in calibration millimetres (forward +X,
up +Y, left +Z).
The polygon man is a coarse stand-in on Human's skeleton and carries only
the form it needs, so nothing here builds, fits or measures a curve of the
detailed figure: no trunk tape or course is closed, no neck girth is
solved, no head mass or surface is prepared. The detailed figure keeps its
own bind skeleton (AutoMovieHumanBodyLaw.prepare), whose trunk joints
stand on its converged surface.
What each joint is placed from:
Legs, feet and toes: AutoMovieHumanLimbRest from the public limb
inputs and the body frame's perineal datum, as the detailed figure
places them.
Neck base, neck radius, atlas, head and crown: the neck prior's affine
axis and tape radius (AutoMovieHumanNeckSource) and the head's landmark
layout (AutoMovieHumanHeadLandmarks.layout), the head joint on the
cranial centre at the tragion's published drop under the vertex. These
are the values the detailed head lane publishes.
Jaw and eyes: the same layout's median profile at the nasion and its eye
openings, by the rule of AutoMovieHumanHeadLane.prepare.
Shoulders and arms: the acromion and the glenohumeral centre of
AutoMovieHumanShoulderDatum, its neck support the neck's tape radius
at the neck base. The detailed figure reads the support from its solved
neck-base course instead, which moves the glenohumeral centre by a few
hundredths of a millimetre at most on the motion population.
Spine, chest and the sternoclavicular joints' forward place: on the
straight line from the mid-hip to the neck base, at the heights the
skeleton law already gives them. This is the polygon man's own
definition of its trunk joints, directed by the project owner: no
published source in the package gives the vertebral column's forward
place at these levels, and the detailed figure's column axis, the middle
of its converged sections' depth, belongs to that figure's surface. The
line is the simplest construction through the two joints the skeleton
level does place.
The polygon man's bind joints, placed from the person's parameters by closed-form placement laws alone, in calibration millimetres (forward +X, up +Y, left +Z).
The polygon man is a coarse stand-in on Human's skeleton and carries only the form it needs, so nothing here builds, fits or measures a curve of the detailed figure: no trunk tape or course is closed, no neck girth is solved, no head mass or surface is prepared. The detailed figure keeps its own bind skeleton (
AutoMovieHumanBodyLaw.prepare), whose trunk joints stand on its converged surface.What each joint is placed from:
AutoMovieHumanLimbRestfrom the public limb inputs and the body frame's perineal datum, as the detailed figure places them.AutoMovieHumanNeckSource) and the head's landmark layout (AutoMovieHumanHeadLandmarks.layout), the head joint on the cranial centre at the tragion's published drop under the vertex. These are the values the detailed head lane publishes.AutoMovieHumanHeadLane.prepare.AutoMovieHumanShoulderDatum, its neck support the neck's tape radius at the neck base. The detailed figure reads the support from its solved neck-base course instead, which moves the glenohumeral centre by a few hundredths of a millimetre at most on the motion population.