Cross-product magnitudes used by contour emission to require finite positive
area before and after conversion to metres. Each value is twice triangle area.
The metre computation converts positions before subtraction, so it is not
obtained by scaling the millimetre result and may expose different rounding.
Cross-product magnitudes used by contour emission to require finite positive area before and after conversion to metres. Each value is twice triangle area. The metre computation converts positions before subtraction, so it is not obtained by scaling the millimetre result and may expose different rounding.