AutoMovie API
    Preparing search index...

    Variable serviceSystemLoadConst

    serviceSystemLoad: (props: IAutoMovieServiceSystemLoad.IProps) => number = ...

    Total demand one system is declared to carry, in the system's own unit.

    The load is read at the ports facing opposite to the root, because that is the end a system is loaded from. A supply main, a lighting circuit and a supply air trunk are loaded by what their in ports draw; a drainage stack, a return riser and an exhaust are loaded by what their out ports discharge. Summing in ports for every system would leave every to-root system measured against a load of zero — a capacity check that cannot fail is worse than none, because it reads as one that passed.

    A fitting merely passing the medium on — a tee, a valve, a damper — declares 0 and contributes nothing, so the water that reaches a basin through a shut-off is counted where the basin draws it and not again at the valve. A bidirectional port is counted at neither end: it is the fitting on a ring that may be fed from either side, and a tap's draw is stated on the port that draws it rather than on the ring it hangs off.

    This is a declaration check and nothing more. No diversity, no simultaneity and no head loss enter it; serviceAnalysisSupport names the solver that would as unsupported.

    Type Declaration