AutoMovie API
    Preparing search index...

    Interface IAutoMovieAcousticRequest

    Everything one room-acoustic study is configured with.

    analyzeAutoMovieAcoustics throws on a blank id, subject or revision, a non-positive volume, an empty surface list, any malformed or repeated member, more receivers than AUTOMOVIE_ANALYSIS_MAX_SAMPLES, or a malformed target. Every field except id, subject and inputRevision enters the settings digest; those three go into the run header.

    interface IAutoMovieAcousticRequest {
        id: string;
        inputRevision: string;
        partitions: readonly IAutoMovieAcousticPartition[];
        receivers: readonly IAutoMovieAcousticReceiver[];
        sources: readonly IAutoMovieAcousticSource[];
        subject: string;
        surfaces: readonly IAutoMovieAcousticSurface[];
        targets: readonly IAutoMovieAnalysisTarget[];
        volume: number;
    }
    Index
    id: string

    Stable run identity; non-blank.

    inputRevision: string

    Design revision being read; non-blank.

    partitions: readonly IAutoMovieAcousticPartition[]

    Partitions whose composite transmission loss is asked for; empty makes that metric a gap.

    receivers: readonly IAutoMovieAcousticReceiver[]

    Listening positions the field is reported at; at most AUTOMOVIE_ANALYSIS_MAX_SAMPLES, and empty makes the level metrics a gap.

    sources: readonly IAutoMovieAcousticSource[]

    Steady sources inside the room; empty makes every level metric a gap.

    subject: string

    Logical space being listened to; non-blank.

    surfaces: readonly IAutoMovieAcousticSurface[]

    Absorbing surfaces; at least one, ids unique.

    targets: readonly IAutoMovieAnalysisTarget[]

    Targets the production declares for this study; a key naming no reported metric becomes a target-key-unknown warning.

    volume: number

    Room volume in m^3; finite and strictly positive.