Stable run identity; non-blank.
Design revision being read; non-blank.
Partitions whose composite transmission loss is asked for; empty makes that metric a gap.
Listening positions the field is reported at; at most
AUTOMOVIE_ANALYSIS_MAX_SAMPLES, and empty makes the level metrics a gap.
Steady sources inside the room; empty makes every level metric a gap.
Logical space being listened to; non-blank.
Absorbing surfaces; at least one, ids unique.
Targets the production declares for this study; a key naming no reported
metric becomes a target-key-unknown warning.
Room volume in m^3; finite and strictly positive.
Everything one room-acoustic study is configured with.
analyzeAutoMovieAcousticsthrows on a blank id, subject or revision, a non-positive volume, an empty surface list, any malformed or repeated member, more receivers thanAUTOMOVIE_ANALYSIS_MAX_SAMPLES, or a malformed target. Every field exceptid,subjectandinputRevisionenters the settings digest; those three go into the run header.